Skip to main content
Corvus
Corvus surveyor scanning a stairwell wall through a grid sheet
REINFORCEMENT SURVEY

Cover Depth

Measure cover depth to design and code requirements with calibrated electromagnetic equipment.

CSCS Registered Same-day call-back Marks before we leave Canary Wharf, UK-wide
What it is

Measure the cover before the fixing goes in.

Cover depth controls the durability of every reinforced element. We measure cover to BS EN standards, log statistics across the element, and flag bars that fall short of design or code.

Hilti PS 300 Ferroscan screen showing the bar layout in a roof slab
Ferroscan on the PS 300, bar layout in a roof slab

Where it helps

  • When cover depth must be verified for compliance
  • Before drilling small-diameter fixings
  • When GPR resolution is insufficient at shallow depth
  • When a structural engineer needs reinforcement detail
  • During defect investigation on a reinforced element
  • For pre-condition surveys on heritage structures

What you receive

  • Bar position plan with measured depths
  • Estimated bar diameter table
  • Cover-depth statistics versus design
  • Annotated PDF report with photographs
  • Digital plan in DXF / DWG

A note on interpretation. Ferro scanning measures cover depth and bar spacing; bar diameter is estimated where conditions allow. Readings are indicative of the reinforcement detected and should be verified against design before any compliance decision.

Need cover depths you can trust?

Send drawings, photos or proposed fixing locations and we'll advise the right survey approach.

Call 020 3886 3660 Get a Quote